Meio Original bem aberto 12v 160W Única Saída Médica Tipo RPS-160-12
Descrição do produto
MODEL | RPS-160-12 | |
OUTPUT | DC VOLTAGE | 12V |
RATED CURRENT | 12.9A | |
CURRENT RANGE | 0 ~ 12.9A | |
RATED POWER | 112.2W | |
PEAK LOAD(23.5CFM) | 159.8W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | |
VOLTAGE ADJ. RANGE | 10.8 ~ 13.2V | |
VOLTAGE TOLERANCE Note.3 | ±3.0 % | |
LINE REGULATION | ±0.5 % | |
LOAD REGULATION | ±1.0 % | |
SETUP, RISE TIME | 1800ms, 30ms/230VAC 3500ms , 30ms/115VAC at ful l load | |
HOLD UP TIME (Typ.) | 16ms/230VAC 20ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 87% | |
AC CURRENT (Typ.) | 2A/115VAC 1.1A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 25A/115VAC 50A/230VAC | |
LEAKAGE CURRENT Note.7 |
Earth leakage current less than 200µA / 264VAC, Touch current less than 100µA/264VAC |
|
PROTECTION | OVERLOAD | 105 ~ 135% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 13.8 ~ 16.2V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
ENVIRONMENT | WORKING TEMP. | -20~ +70°C (Refer to derating curve) |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +85°C , 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 45°C) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY & EMC (Note 4) | SAFETY STANDARDS | ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | |
EMC EMISSION |
Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2,EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A |
|
OTHERS | MTBF | 230.5K hrs min. MIL-HDBK-217F (25°C ) |
DIMENSION | 127*76.2*34.6mm (L*W*H) | |
PACKING | 0.32Kg; 36pcs/12.5Kg/0.79CUFT | |
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. |
|
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||
3. Tolerance: includes set up tolerance, line regulation and load regulation. | ||
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directive. | ||
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. | ||
6. Heat Sink HS1,HS2 can not be shorted. | ||
7. Touch current was measured from primary input to DC output. | ||
8. Suitable for BF application with appropriate system consideration |
Grupo de Produto : Fonte de Alimentação Bem Aberta 5W ~ 400W > Fonte de alimentação médica série MPS / RPS 30W ~ 400W