MEAN WELL PSC-60A com carregador de bateria 13.8VDC saída 60W MW fonte de alimentação UPS
Descrição do produto
MODEL | PSC-60A( UPS power supply ) | ||
OUTPUT | OUTPUT NUMBER | CH1 | CH2 |
DC VOLTAGE | 13.8V | 13.8V | |
RATED CURRENT | 2.8A | 1.5A | |
CURRENT RANGE | 0 ~ 4.3A | -------- | |
RATED POWER | 59.34W | ||
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | -------- | |
VOLTAGE ADJ. RANGE | CH1: 12 ~ 15V | ||
VOLTAGE TOLERANCE Note.3 | ±1.0% | -------- | |
LINE REGULATION | ±0.5% | -------- | |
LOAD REGULATION | ±0.5% | -------- | |
SETUP, RISE TIME | 800ms, 50ms/230VAC 1600ms, 50ms/115VAC at full load | ||
HOLD UP TIME (Typ.) | 50ms/230VAC 10ms/115VAC at full load | ||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | |
FREQUENCY RANGE | 47 ~ 63Hz | ||
EFFICIENCY (Typ.) | 84% | ||
AC CURRENT (Typ.) | 1.6A/115VAC 1A/230VAC | ||
INRUSH CURRENT(Typ.) | COLD START 30A/115VAC 60A/230VAC | ||
LEAKAGE CURRENT | Less than 1mA /240VAC | ||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||
OVER VOLTAGE | CH1:14.49 ~ 18.63V | ||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||
BATTERY LOW | 10.5V± 0.5V | ||
FUNCTION | AC OK | TTL open collector output, ON : AC OK ; OFF : AC Fail ; Ice : max. 30mA at 50VDC | |
BATTERY LOW |
TTL open collector output, ON: Battery Low ; OFF : Battery OK ; Ice : max. 30mA at 50VDC |
||
Battery low voltage : < 11V | |||
ENVIRONMENT | WORKING TEMP. | -20 ~ +70°C (Refer to derating curve) | |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||
STORAGE TEMP., HUMIDITY | -20 ~ +85°C , 10 ~ 95% RH | ||
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) on CH1 output | ||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved | |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25°C/ 70% RH | ||
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | ||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A |
||
OTHERS | MTBF | 589.7K hrs min. MIL-HDBK-217F (25°C ) | |
DIMENSION | PCB:101.6*50.8*29mm (L*W*H) ; | ||
with optional CASE:103.4*62*37mm (L*W*H) | |||
PACKING | PCB:0.13Kg; 96pcs/13.5Kg/0.89CUFT ; | ||
with optional CASE:0.29Kg; 45pcs/14Kg/0.67CUFT | |||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. |
||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||
3. Tolerance: includes set up tolerance, line regulation and load regulation. | |||
4. The power supply is considered as a component that will be operated in combination with final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | |||
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. | |||
6. Heat sink HS1,HS2 can not be shorted. | |||
7. Heat sink HS1 must have safety isolation distance with system case. |
Grupo de Produto : Fonte de Alimentação Bem Aberta 5W ~ 400W > Série NFM médica 5W ~ 20W